Avago Technologies LSI53C825AE User Manual

Page 139

Advertising
background image

Operating Registers

4-51

•

The LSI53C825A is selected

•

The LSI53C825A is reselected

•

A SCSI gross error occurs

•

An unexpected disconnect occurs

•

A SCSI reset occurs

•

A parity error is detected

•

The handshake-to-handshake timer is expired

•

The general purpose timer is expired

To determine exactly which condition(s) caused the
interrupt, read the

SCSI Interrupt Status Zero (SIST0)

and

SCSI Interrupt Status One (SIST1)

registers.

DIP

DMA Interrupt Pending

0

This status bit is set when an interrupt condition is
detected in the DMA portion of the LSI53C825A. The
following conditions cause a DMA interrupt to occur:

•

A PCI parity error is detected

•

A bus fault is detected

•

An abort condition is detected

•

A SCRIPTS instruction is executed in single step
mode

•

A SCRIPTS interrupt instruction is executed

•

An illegal instruction is detected

To determine exactly which condition(s) caused the
interrupt, read the

DMA Status (DSTAT)

register.

Advertising