5.1.2 Hardware Specifications

Specification

Description

Backplane Current Load

800 mA @ 5 VDC
3 mA @ 24 VDC

Operating Temperature

0°C to 60°C (32°F to 140°F)

Storage Temperature

-40°C to 85°C (-40°F to 185°F)

Shock

30 g operational
50 g non-operational
Vibration: 5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (without condensation)

LED Indicators

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Debug/Configuration port (CFG)

CFG Port (CFG)

RJ45 (DB-9M with supplied cable)
RS-232 only

Application ports (PRT1 & PRT2)

Full hardware handshaking control, providing radio, modem and multi-drop support

Software configurable
communication parameters

Baud rate: 110 to 115,200 baud, depending on
protocol
RS-232, 485 and 422
Parity: none, odd or even
Data bits: 5, 6, 7, or 8
Stop bits: 1 or 2
RTS on/off delay: 0 to 65535 milliseconds

App Ports (P1, P2) (Serial
modules)

RJ45 (DB-9M with supplied cable)
RS-232 handshaking configurable
500V Optical isolation from backplane

Shipped with Unit

RJ45 to DB-9M cables for each port
6-foot RS-232 configuration cable

5.1.3 Functional Specifications

DF1 ports
 Full and half duplex modes supported
 CRC and BCC error checking
 Full hardware handshaking control provides radio, modem and multi-drop

support

 User-definable module memory usage, supporting the storage and transfer of

up to 5000 registers to/from the control processor

 Up to 125 word read and write command lengths supported
 Floating point data movement supported