Reference

MVI56-DFCM ♦ ControlLogix Platform

User Manual

DF1 Half/Full Duplex Master/Slave Serial Communication Module

Page 74 of 106

ProSoft Technology, Inc.

September 24, 2014

All data transferred between the module and the processor over the backplane is
through the input and output images. Ladder logic must be written in the
ControlLogix processor to interface the input and output image data with data
defined in the Controller Tags. All data used by the module is stored in its internal
database. The following illustration shows the layout of the database:

Module’s Internal Database Structure

5000 registers for user data

0

Register Data

4999

3400 words of configuration and
status data

5000

Status and Config

8399

Data contained in this database is paged through the input and output images by
coordination of the ControlLogix ladder logic and the MVI56-DFCM module's
program. Up to 248 words of data can be transferred from the module to the
processor at a time. Up to 247 words of data can be transferred from the
processor to the module. The read and write block identification codes in each
data block determine the function to be performed or the content of the data
block. The block identification codes used by the module are listed below:

Block Range

Descriptions

-9000

Configuration data (sent from module)

-7100

Port 2 Override File Maps (sent from module)

-7000

Port 1 Override File Maps (sent from module)

-6100 to -6104

Port 2 commands (sent from module)

-6000 to -6004

Port 1 commands (sent from module)

-1

Null block

0

Null block

1 to 999

Read or write data

1000

Event Port 1

2000

Event Port 2

3000 to 3001

Port 1 slave polling control

3002 to 3003

Port 1 slave status

3100 to 3101

Port 2 slave polling control

3102 to 3103

Port 2 slave status

5000 to 5006

Port 1 command control

5100 to 5106

Port 2 command control

6000 to 6004

Port 1 commands (sent to module)