PDPM ♦ ProLinx Gateway

Diagnostics and Troubleshooting

PROFIBUS DP Master

Protocol Manual

ProSoft Technology, Inc.

Page 53 of 70

June 24, 2013

Error
Number

Description

0

No error

4

Task does not exist

5

Task is not initialized

6

The MCL is locked

7

The MCL rejects a send command because of an error

20

Database not configured

21

Data base segment not configured or not existent

22

Number for message wrong during download

23

Received number of data during download does not match to that in the command
message

24

Sequence identifier wrong during download

25

Checksum after download and checksum in command message does not match

26

Write/Read access of data base segment

27

Download/Upload or erase of configured data base type is not allowed

28

The state of the data base segment indicated an error. Upload not possible

29

The access to the database segment needs the bootstrap loader. The bootstrap
loader is not present

30

Trace buffer overflow

31

Entry into trace buffer too long

37

No or wrong license. The OEM license of the system configuration allows only
communication to devices that have the same license inside

38

The database created by the system configuration and the database expected by the
firmware is not compatible

39

DBM module missing

40

No command free

41

Command unknown

42

Command mode unknown

43

Wrong parameter in the command

44

Message length does not match to the parameters of the command

45

Only a MCL does use this command to the RCS

50

FLASH occupied at the moment

51

Error deleting the FLASH

52

Error writing the FLASH

53

FLASH not configured

54

FLASH timeout error

55

Access protection error while deleting the FLASH

56

FLASH size does not match or not enough FLASH memory

60

Wrong structure type

61

Wrong length of structure

62

Structure does not exist