Inhibiting cross-point button operations – Sony Multi Interface Shoe Adapter User Manual

Page 110

Advertising
background image

110

Signal Selection

Chapt

er

3

S

ign
al Sele

c

tio

n

a

nd T

ran
s

itio
n

s

Note

You can use the rightmost button (number 12) as a [SIDE FLAG] button. In
this case, the shift button moves one to the left, to number 11, and the button
numbers are offset by one.

For details of the [SIDE FLAG] button, see “Cross-Point Settings (Xpt Assign
menu)” in Chapter 16 (Volume 2).

Inhibiting cross-point button operations

For each cross-point button, you can temporarily inhibit operations.

Note

This setting is cleared when you reset the control panel.

Assigning a button to the function of disabling cross-point button
operation

You can assign the button to be used for the operation to a user preference
button, in setup. The [Inhibit All Clear] function is also assigned to this button.

(See “Setting Button Assignments (Prefs/Utility menu)” in Chapter 19 (Volume
3))

Buses for which operations can be inhibited

This setting applies to the auxiliary bus control block and the cross-point
buttons in each switcher bank.

For example, if you make the setting for one cross-point button in a switcher
bank, this inhibits operation of all cross-point buttons with the same number in
the following buses.
The corresponding name also disappears from the source name display.
• Background A, background B
• Keys 1 to 4
• Utility
• External DME

To inhibit operation of a cross-point button

Hold down the button which “Inhibit Set” is assigned, and press the cross-point
button whose operation you want to inhibit.
The button you pressed flashes amber, and this makes the operation inhibited.

Note

Even when you inhibit operation of a cross-point button, macro attachment
settings are still possible (

see “Setting and Canceling a Macro Attachment” in

Chapter 16 (Volume 2)

).

Advertising