A.5

MODULAR CABLING USING M24SII-V06A I/O
MODULE

COMPUTER INTERFACE
To interface your computers or terminals to the Model 24SII using

EIA-232

protocol, refer to the RJ-45 adapter drawings below. Refer to

Figure 13

if your computers or terminals have DB-25 male connectors

(most IBM XT and PS/2 type computers). Refer to

Figure 14

if your

computers have DE-9 male connectors (IBM AT type computers).

1

2

3

4

5

6

7

8

20

8

7

6

5

4

3

2

RTS

RX

DCD

DTR

GND

DSR

TX

CTS

FEMALE DB-25

RJ-45

BLUE

ORANGE

BLACK

RED

GREEN

YELLOW

BROWN

GRAY

Figure 13

       

     !"# $  %!&&"'() *+ +, +-

     !" $  %!&&"'(. *+ +,  +-

RJ-45

FEMALE DE-9

DTR

DCD

GND

DSR

CTS

RTS

RX

TX

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

1

GRAY

BROWN

YELLOW

GREEN

RED

BLACK

ORANGE

BLUE

Figure 14

     

    / !"# $  %!&&"'() *+ +, +-

    / !" $  %!&&"'(. *+ +,  +-