3.

Refer to the upper right hand corner of the screen for
Handshaking line status. RTS, CTS, DSR, and DTR
should all be HIGH. The DCD line is not looked at by the
terminal emulation program therefore its status can be
ignored. If these signals are not high at this point, check
to ensure the correct cable is connected.

4.

Ensure that all red LEDs on the front of the Model 24SII
DES are off (all ports off-line), and that the green 'power
on' LED is illuminated.
You may now configure the Model 24SII DES from the
PC keyboard.
NOTE: Keyboard entries must be CAPITAL
LETTERS. Put your keyboard in the CAPS LOCK
mode.

5.

Depress function key: F1 followed by the module
number that you wish to configure (1 to 6).

NOTE: The F1 key in TERM sends the character
sequence

Control-T

(14 Hex) followed by the ASCII

capital C character (43 Hex).

The main configuration menu for the selected module will appear.
From this point on, configuration of the Model 24SII DES will be
accomplished by following the plain-English menus that will prompt
you. Enter the letter corresponding to the desired operation. Refer to
the chart provided on the following page for assistance.

NOTE: Once F1 and the desired module number are sent, the LEDs
for Port 1 and the ports for the selected module on the front of the
Model 24SII DES will illuminate and will remain illuminated while you
are in configuration mode. If only two LEDs illuminate, if no LEDs
illuminate, or if no menus appear, this indicates that an incorrect
character sequence has been received. If this occurs, wait for all red
LEDs to go out and re-send F1 followed by the desired module
number (1 to 6).