If you are connecting an EIA-232 device to the M24SII-V07 module
using 8-wire Operation, please see

Appendix A.5

for device adapter

pinouts and recommended cabling.

When connecting an EIA-422 device to the M24SII-V07 module using
8-wire Operation, the cable required to connect the two devices must
have TX+ wired to RX+ (and vice versa), TX- wired to RX- (and vice
versa), HSO wired to HSI (and vice versa), and have the signal
grounds connected. Please

Figure 9

.

M24SII-V07 (EIA-422, 8-wire) Equipment
RJ-45 Connections

1 HSO HSI
2 GND GND
3 TX+ RX+
4 TX- RX-
5 RX- TX-
6 RX+ TX+
7 GND GND
8 HSI HSO

Figure 9: M24SII-V07 EIA-422 (8-wire) Connection

If you are connecting an EIA-422 device other than another BayTech
product, you must refer to the operator's manual for your equipment to
determine which pins are defined as TX+, TX-, RX+, RX-, HSI, HSO,
and signal ground (common).

If you are connecting another BayTech product (such as Tran-x) using
EIA-422 protocol and 8-wire Operation, please refer to

Appendix

A.7.1

for the recommended cable pinout.