2.4.2 CAN bus indicator LED

The i-7540D includes three single-color LED displays to indicate the status of

module, network and I/O device. They are ER LED (it is red), TX LED (it is green),
and RX LED (it is red). The Indicators assist maintenance personnel in quickly
identifying a problem unit. The LED test is to be performed at power–up. When
the CAN communication events occur, these indicators will be triggered to glitter
with different conditions.

z

ER

LED

This LED provides device status and indicates whether or not the device is
operating properly. Table 2-6 shows the conditions of ER status. Therefore, when
the device is operated normally, the ER-LED must be turned off.

If this led flashing

red,

u

sers can use the “99S” command, in section 4.5, to read the status of the

i-7540D

.

Table 2-6 ER-LED conditions

Condition Description
Off

Device is normal; no error occurs

Red

Device has unrecoverable fault

Flashing red Device has recoverable fault.

To recover:
Reset device or perform error recovery

z

TX

LED

This LED indicates the status of message transmitted. Table 2-7 shows the
conditions of TX status. Therefore, when the device transmits messages to the
CAN bus, the TX-LED is normally flashing green.

Table 2-7 TX led conditions

Condition Description
Off

No data is being transmitted to the CAN side

Flashing green Data are transmitting to the CAN side

Solid green

Transmit data error