5 99s – ICP DAS USA I-7540D User Manual

Page 63

Advertising
background image

4.5

99S

Description: Read the i-7540D CAN Baud Rate and error flag message.

¾

Syntax: 99S

99S

Command character.

¾

Response:

Valid Command: !CFFTTRRO<CR>

Invalid command: ERROR

!

Delimiter for valid command

C

current baud rate setting of CAN

FF

CAN register

TT

CAN transmit error counter

RR

CAN receive error counter

O

CAN FIFO Overflow flag

¾

Note:

Furthermore, all response results are shown in the ASCII format. Users
need to make an ASCII to hex format transformation in order to
understand what the meaning is based on the 4-2, 4-3, 4-4 tables.

Table 4-3: CAN baud rate list

AsciiToHex(C)

Description

0

10K baud rate of CAN

1

20K baud rate of CAN

2

50K baud rate of CAN

3

100K baud rate of CAN

4

125K baud rate of CAN

5

250K baud rate of CAN

6

500K baud rate of CAN

7

800K baud rate of CAN

8

1000K baud rate of CAN

9 User

defined











i-7540D CAN-Ethernet Gateway User’s Manual (Version 1.4, April/2008)

63