8 - replacing the internal sensor, 8 replacing the internal sensor – Lennox Hearth G8 User Manual

Page 101

Advertising
background image

5.8

Replacing the Internal Sensor

1. Disconnect the sensor cable from the internal

sensor assembly.

2. Using a

3

8

" nut driver/socket, remove the four

#10-32 self-locking nuts and flat washers securing
the internal sensor assembly to the sensor bracket.
Remove the old internal sensor.

3. Install the new internal sensor. Secure in place

with the nuts/washers that you removed in Step 2
and reconnect the sensor cable.

4. With Autocalibration set to “ON,” the sensor will

calibrate itself when you power up the antenna
and maneuver the vessel. The factory default
setting for Autocalibration is “ON” (see

“Selecting

Autocalibration” on page 78

).

Maintenance

54-0198

103

Figure 5-16
Internal Sensor Assembly
(Side View)

Figure 5-17
Internal Sensor Assembly
(Top View)

Sensor Cable
Connector

Internal

Sensor

#10-32 Self-locking

Nuts (x 4)

Sensor Bracket

Advertising