INSTALLATION

A-2

A-2

INVERTEC® V450-PRO

TECHNICAL SPECIFICATIONS -

INVERTEC® V450-PRO

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS-

FREQUENCY

208/230/460/575V - 60HZ.

200/220/440/575V - 50HZ.

INPUT

VOLTAGE /

FREQUENCY

208/50/60HZ
230/50/60HZ
460/50/60HZ
575/50/60HZ

HEIGHT

26.10 in

663 mm

WIDTH

19.86 in

505 mm

DEPTH

32.88 in

835 mm

WEIGHT

293 lbs.

133 kg.

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

100
100

50
40

TYPE 75°C

GROUND WIRE IN

CONDUIT AWG(MM

2

)

SIZES

8(10)
8(10)
10(6)
10(6)

TYPE 75°C

COPPER WIRE IN

CONDUIT AWG(MM

2

)

SIZES

4(25)
4(25)
8(10)
10(6)

MIG/MAG

FCAW

SMAW

GTAW

Pulse

50-570 Average Amps
40-570 Average Amps
55-570 Average Amps

5-570 Average Amps

5-750 Peak Amps

30-76

76
76

18-76

76

PULSE

VOLTAGE

RANGE

5 - 55 VDC

AUXILIARY POWER

(CIRCUIT BREAKER PROTECTED)

24VAC

42VAC AT

10 AMPS

115VAC AT

15* AMPS

PULSE AND

BACKGROUND

TIME RANGE

100 MICRO SEC. -3.3

SEC.

PULSE

FREQUENCY

0.15 - 1000 Hz

INPUT

CURRENT

AMPS

58/53/25/22
82/78/37/31

49/45/23/18
67/61/31/25

IDLE

POWER

400 Watts

Max.

POWER FACTOR

@ RATED OUTPUT

.95 MIN.

EFFICIENCY

@ RATED

OUTPUT

88%

OUTPUT

CONDITIONS

AMPS / VOLTS / DUTY CYCLE

[email protected]%

570A@43V. 60%

[email protected]%

500A@40V. 60%

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-40°C to +40°C

OPEN CIRCUIT VOLTAGE PROCESS CURRENT RANGE (DC) CURRENT

* Earlier models used 10 amps circuit breaker.