INPUT CONTACTOR TEST PROCEDURE (continued)

PROCEDURE

1. Remove input power to the INVERTEC®

V450-PRO.

2. Using the 3/8” nut driver, remove the input

access panel and case top.

3. Locate, mark, and remove the two leads (601,

X4) that are connected to the input contactor
coil. See Figure F.4.

4. Using the external 24 VAC supply, apply 24

VAC to the terminals of the input contactor coil.
If the contactor does NOT activate, the input
contactor is faulty. Replace.

TROUBLESHOOTING AND REPAIR

F-26

F-26

INVERTEC® V450-PRO

INPUT

CONTACTOR

601

X4

INPUT
CONTACTOR

601

X4

FIGURE F.4 – INPUT CONTACTOR COIL