background image

SWITCH BOARD

SWITCH BOARD

FIGURE F.23 – SWITCH BOARD LOCATION

SWITCH BOARD AND FILTER CAPACITOR

REMOVAL AND REPLACEMENT (continued)

REMOVAL PROCEDURE

NOTE: Observe all static electricity precautions.

Lead and plug references below use a slash (/) to
indicate machine right side/left side wire number
differences.

1. Remove input power to the V450-PRO.

2. Using the 3/8” nut driver, remove the case top

and sides.

3. Perform the Capacitor Discharge Procedure.

4. Using the 3/8” nutdriver, remove the screw

mounting the plastic high voltage protective
shield. Remove the shield and it’s mount from
the machine.

5. Remove molex plug J50 from the top of the

switch board. See Figure F.24.

6. Remove the mylar insulating shield covering

leads 13/14 or 17/18 (marked clearly on the
board). Cut any necessary cable ties.

7. Using the 7/16” wrench, remove leads 13/14 or

17/18 from the switch board. See Figure F.24.

8. Using the 7/16” wrench, remove leads 11/12 or

15/16 from the switch board. See Figure F.24.

9. Using the 7/16” wrench, remove leads 19C/D+

and 20C/D- from the switch board capacitor
connection bolts. See Figure F.24.

10. With the slot head screwdriver, remove the

two nylon mounting screws at the bottom of
the switch board. Note placement of the
shake-proof washers and fiber spacers.

11. Using the 3/16” allen wrench, carefully remove

the four cap screws that mount the switch
board to the heat sink.

12. Carefully remove the switch board from the

heat sink.

13. If the filter capacitor is to be removed, careful-

ly slide it out of the mounting bracket.

TROUBLESHOOTING AND REPAIR

F-82

F-82

INVERTEC® V450-PRO