Symptoms, Troubleshooting and repair, Caution – Lincoln Electric INVERTEC SVM199-A User Manual

Page 44

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

TROUBLESHOOTING AND REPAIR

F-4

F-4

INVERTEC® V450-PRO

Major physical or electrical
damage is evident when the
sheet metal covers are removed.

Contact the Lincoln Electric
Service Department at 1-888-
935-3877.

The input fuses repeatedly fail or
the input circuit breakers keep
tripping.

The input fuses fail or input
breakers trip after the CR-1
contactor closes

1. Input fuses or breakers may be

improperly sized.

2. The reconnect panel may not

be configured properly for the
applied voltage.

1. Input fuses or breakers may be

improperly sized.

2. The reconnect panel may not

be configured properly for the
applied voltage.

3. A component in the input

circuitry has failed.

1. Check the reconnect panel

connections and associated
wiring. See the Wiring
Diagram and Input
Information
in Section A for
the proper input voltage.
Check the input voltage and
make sure it is correct.

1. Check the re-connect panel

connections and associated
wiring. See the Wiring
Diagram and Input
Information
in Section A.

2. Perform the Input Rectifier

Test. If the Input Rectifier is
defective, perform tests 3 and
4.

3. Perform the IGBT Switch

Board Test.

4. Perform the Input Board Test

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising