Troubleshooting and repair, Input rectifier test procedure (continued) – Lincoln Electric INVERTEC SVM199-A User Manual

Page 63

Advertising
background image

INPUT RECTIFIER TEST PROCEDURE (continued)

6. Use the analog ohmmeter to perform the tests

detailed in Table F.1.

7. If the input rectifier does not meet the accept-

able readings outlined in the table, the compo-
nent may be faulty. Replace.

NOTE: Before replacing the input rectifier, perform

the Switch Board Test and the Input
Contactor Test.

8. When installing a new input rectifier, see Input

Rectifier Removal and Replacement proce-
dure.

9. If the input rectifier is good, be sure to recon-

nect the positive and negative leads to the cor-
rect terminals and torque to 31 in.-lbs. See the
Wiring Diagram.

10. Replace any RTV sealant previously removed.

11. Install the case top.

TROUBLESHOOTING AND REPAIR

F-23

F-23

INVERTEC® V450-PRO

TEST POINT TERMINALS

A
B

C

A
B

C

NEG
NEG
NEG

POS
POS
POS

NEG
NEG
NEG

POS
POS
POS

A
B

C

A
B

C

Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms

Approx. 500 ohms
Approx. 500 ohms
Approx. 500 ohms

Approx. 500 ohms
Approx. 500 ohms
Approx. 500 ohms

Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms

TABLE F.1 – INPUT RECTIFIER TEST POINTS AND ACCEPTABLE READINGS

ANALOG METER X100

RANGE

Acceptable Meter Readings

+ Probe

- Probe

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising