Troubleshooting and repair, Auxiliary transformer no. 2 test (continued), Warning – Lincoln Electric INVERTEC SVM199-A User Manual

Page 74

Advertising
background image

TRANSFORMER #2

3/8” MOUNTING

SCREWS (2)

P51

P52

P50

TRANSFORMER #2

3/8” MOUNTING
SCREWS (2)

P51

P52

P50

FIGURE F.7 – PLUGS P52 AND P54

AUXILIARY TRANSFORMER NO. 2 TEST (continued)

TROUBLESHOOTING AND REPAIR

F-34

F-34

INVERTEC® V450-PRO

PROCEDURE

1. Remove the main input supply power to the

INVERTEC® V-450 PRO.

2. Remove any load that may be connected to the

115 VAC receptacle.

3. Using the 3/8 in. nut driver, remove the left and

right case sides.

4. Perform the Capacitor Discharge Procedure.

5. Locate plugs P50 and P51 at the Auxiliary

Transformer No. 2. See Figure F.7.

6. Carefully apply the correct input power and

check for 115 VAC at plug P51 pins #1 and #4.

7. If 115 VAC is present, the Auxiliary Transformer

No. 2 is good.

8. If 115 VAC is not present between pins #1 and

#4, check the associated leads and plugs for
loose or faulty connections.

High voltage is present at plug P50.

9. Carefully test for the correct AC input voltage

applied to the primary windings at H6 and H1.
(P50 Pins 1 and 5) Normal is 550-575 VAC.
See wiring diagram.

10. If the correct AC input voltage is applied to the

primary of the Auxiliary Transformer No. 2 and
the secondary voltage is NOT correct, the
transformer may be faulty. Replace.

11. Install the left and right case sides using the

3/8 in. nut driver.

WARNING

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising