POWER BOARD

CONTROL BOARD

COMPARTMENT

COVER

POWER BOARD

CONTROL BOARD

COMPARTMENT
COVER

FIGURE F.16 – BOARD LOCTION

CONTROL OR POWER BOARD

REMOVAL AND REPLACEMENT PROCEDURE (continued)

REMOVAL PROCEDURE

1. Remove input power to the V450-PRO.

2. Remove the case top, sides and front.

3. Perform the Capacitor Discharge

Procedure.

4. Observe all static electricity precautions.

5. Using the 3/8 in. nut driver, remove the PC

board compartment cover. Refer to Figure
F.16.

6. Remove the molex plugs from the control

board.

7. Label and remove the two molex plugs and

white and black wires with quick connects from
the power PC board.

8. Using the 3/8 in. nut driver, remove the two

screws holding the rear of the Control Box in
place.

9. Clear the lead harnesses from the left and right

sides, and carefully remove the power and con-
trol PC board assembly.

10. Remove either the power or the control board

from the PC board assembly.