Machine shuts down during a weld, Troubleshooting and repair, Caution – Lincoln Electric INVERTEC SVM199-A User Manual

Page 49

Advertising
background image

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

TROUBLESHOOTING AND REPAIR

F-9

F-9

INVERTEC® V450-PRO

Machine shuts down during a weld.

NOTE: The Diagnostic Utility can

be used to check the
‘event log’ to determine
cause of shut-down.

1. Secondary over-current

occurred.

1. Adjust parameters to minimize

momentary shorting of the arc.

2. Check for single phase input,

(loss of L2) which will reduce
the secondary current limit.
Check input fuses or current in
all three phases for balance (+/-
5 amps).