AUXILIARY TRANSFORMER NO. 1 REMOVAL AND

REPLACEMENT PROCEDURE (continued)

8. Cut any necessary cable ties and clear the

leads.

9. Using the 3/8” nut driver, remove the two

mounting screws that hold the transformer to
the fan baffle and the machine base.

10. Carefully remove the transformer from the

V450-PRO.

REPLACEMENT PROCEDURE

1. Carefully place the transformer into the V450-

PRO.

2. Install the two mounting screws that hold the

transformer to the fan baffle and the machine
base using the 3/8” nut driver.

3. Reconnect plug P59 and lead 41B.

4. Reconnect all primary and secondary leads.

See Wiring Diagram.

5. Reposition any wire leads and install cable ties

as necessary.

6. Install the case back using the 3/8” nut driver.

7. Install the case top, sides, and input access

panel using the 3/8” nut driver.

TROUBLESHOOTING AND REPAIR