To table f.2, Troubleshooting and repair, Input board test procedure (continued) – Lincoln Electric INVERTEC SVM199-A User Manual

Page 72

Advertising
background image

INPUT BOARD TEST PROCEDURE (continued)

TROUBLESHOOTING AND REPAIR

F-32

F-32

INVERTEC® V450-PRO

TABLE F.2 – INPUT BOARD VOLTAGE CHECKS

TEST POINTS

PLUG J61 PIN 8 (H1D)

TO

PLUG J61 PIN 2 (612)

PLUG J61 PIN 10 (T3)

TO

PLUG J61 PIN 2 (T1)

PLUG J60 PIN 3 (238)

TO

PLUG J60 PIN 4 (604)

PLUG J60 PIN 3 (238)

TO

PLUG J60 PIN 5 (232)

LEAD

NUMBERS

J61

J61

J60

J60

EXPECTED

VOLTAGE

READINGS

SAME AS

INPUT

VOLTAGE

A LITTLE LESS

THAN INPUT

VOLTAGE

13 – 15 VDC

13 – 15 VDC

COMMENTS

Present when Input
Switch SW1 is closed.

This is Pre-Charge Voltage and
will normally be present 6 sec-
onds after activating Input Switch
SW1. The Pre-Charge Voltage
should remain for approximately 6
seconds and then be removed.

This is the Coil Voltage for the
Pre-Charge Relay. Normally this
DC Voltage will be present 6 sec-
onds after Input Switch SW1 is
activated. This 13 - 15 VDC will
remain for approximately 6 sec-
onds and then be removed. The
Relay is controlled by the Control
Board. See the Wiring Diagram.

This is the DC Coil Voltage for the
Control Relay. Normally this DC
Voltage will be present approxi-
mately 12 seconds after Input
Switch SW1 is activated. The
Relay is controlled by the Control
PC Board. See the Wiring
Diagram.

#612

H1D

T1

T3

#238

#604

#238

#232

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising