INPUT CONTACTOR TEST PROCEDURE (continued)

5. With the input contactor activated, check the

continuity across the three sets of contacts.
(Zero ohms or very low resistance is normal.)
See Figure F.5. If the resistance is high, the
input contactor is faulty. Replace the input con-
tactor.

6. When the contactor is NOT activated, the resis-

tance should be infinite or very high across the
contacts. If the resistance is low, the input con-
tactor is faulty.

7. Reconnect the two leads (601, X4) to the input

contactor coil.

8. Install the input access door and case top using

the 3/8” nut driver.