THERMOSTAT TEST – THERMAL PROTECTION (continued)

TROUBLESHOOTING AND REPAIR

F-48

F-48

INVERTEC® V450-PRO

FIGURE F.11 – THERMOSTAT CIRCUIT

NOTE: Never run the V-450 PRO under load when

any of the thermostats are bypassed. This is
only a means of isolating the inoperative or
open thermostat.

1. Temporarily bypass thermostat circuits with a

shorting jumper as follows:

• All thermostats at the Control Board (2J5 to

3J5)

• Choke thermostat only (224A to 291)

• Output Rectifier thermostat only (220 to 291)

Located on the Output Rectifier Heat Sink

All thermostats are normally closed so moving the
jumper as indicated and watching the Thermal LED
should help determine which thermostat or
associated wiring is defective.

Don’t forget to check the incline splice 224 to 224A as
a possible open.

J

5

-2

J

5

-3

224

220

220

224

224A

291

224A

OUTPUT RECTIFIER

THERMOSTAT

(BOLTED CONNECTION)

CHOKE

THERMOSTAT

(CONNECTED W/EPOXY)

J5

-2

J5

-3

224

220

220

224

224A

291

224A

OUTPUT RECTIFIER

THERMOSTAT

(BOLTED CONNECTION)

CHOKE

THERMOSTAT

(CONNECTED W/EPOXY)

SIMPLIFIED TEST PROCEDURE

LED 6

J5
Thermostat

LED 6

J5

Thermostat

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising