PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

TROUBLESHOOTING AND REPAIR

F-8

F-8

INVERTEC® V450-PRO

General degradation of weld
performance.

1. Wire feed problem.

2. Cabling problems.

3. Verify weld mode is correct for

process.

4. Machine calibration.

1. Check for proper wire speed

and consistent feeding.

2. Check for poor connections

and/or excessive loops in the
weld cables.

NOTE: The presence of heat in

external welding circuits
indicates poor
connections or
undersized weld cables.

3. Select the correct weld mode

for the application. Refer to
the Instruction Manual.

4. Perform Choke Test.

5. Perform Current Transducer

Test and Check Sense Lead
Routing.

WELD AND ARC QUALITY PROBLEMS