Battery, Buzzer, Battery buzzer – Promise Technology VTrak 15110 User Manual

Page 114

Advertising
background image

VTrak 15110 User Manual

106

2.

Click on the VTrak

icon.

3.

Click on the Enclosures

icon.

4.

Click on the Enclosure

icon.

5.

Click on the FRU VPD tab.

Battery

The Enclosure–Battery tab reports on the condition of VTrak's cache backup
battery. Battery Information displays battery temperature, capacity and voltage.
The Advanced Battery Information lists Vital Product Data (VPD), which is
primarily for reference by Technical Support.

There are no user settings for this tab. See Chapter 6 for instructions how to
replace a battery.

To access the Enclosure–Information tab:

1.

Click the Subsystem

icon.

2.

Click on the VTrak

icon.

3.

Click on the Enclosures

icon.

4.

Click on the Enclosure

icon.

5.

Click on the Battery tab.

Buzzer

The Enclosure–Buzzer tab reports on the audible alarm setting. VTrak's audible
alarm has four signals:

Beep-beep, beep-beep, beep-beep: Indicates that one or more Logical
Drives is Critical.

Beep. Beep. Beep: Indicates that one or more Logical Drives is Rebuilding.

Beep-beep-beep, beep-beep-beep: Indicates a problem with an FRU.

10 second continuous beep: Indicates that one or more Logical Drives is
Offline.

The audible alarm has a Silence function which stops it from sounding for the
current event only. If another event happens, the buzzer will sound again.

To change audible alarm setting:

1.

Click the Subsystem

icon.

Advertising