Clu function map – Promise Technology VTrak 15110 User Manual

Page 150

Advertising
background image

VTrak 15110 User Manual

142

11

ST380013AS

80 GB

12

WDC WD1200JD-00FYB0 120 GB

Enter Physical Drive ID to select.
Press R to continue after you have finished
selecting Physical Drive.

Your input?>r

8.

Press R to finish your selection and press Enter.
The Disk Array Properties submenu displays. Note that Hot Spare Policy has
changed to Dedicated with the physical drive 9 (PD9) as the hot spare.

Stripe Block Size: 64K

Disk Array #1 Mapping: GB
-----------------------------------
| 100 GB | 100 GB | 39 GB |
-----------------------------------
--------------------------------------------------------------------------
Name: Daniels Array
RAID Level:

5

Member LDs:

1-2

Stripe Block Size: 64K

Capacity:

240 GB

Member PDs:

1,3-4,7

SMART Check:

On

Cache Policy:

Write Through

Retry Count:

2

Auto Rebuilding: On

Hot Spare Policy: Dedicated(PD9)

Priority: High(RBLD), High(SYNC), High(Migration), High(RC), High(PDM)
--------------------------------------------------------------------------
Disk Array 1 Properties
1. Create Logical Drive
2. Delete Logical Drive
3. Cache Policy
4. Retry Count
5. Enable/Disable SMART
6. Name
7. Priority
8. Hot Spare
9. Auto Rebuilding
R. Return to Previous Menu

Please enter your menu choice>