VTrak’s audible alarm (buzzer) has three sound patterns:

Beep. Beep. Beep. – Indicates that a logical drive is rebuilding

Beep-beep, beep-beep, beep-beep. – Indicates that a logical drive is critical

Beep-beep-beep. Beep-beep-beep. – Indicates a problem with a field
replaceable unit (FRU)

10 second continuous beep – Indicates that a logical drive is offline

See page 189 for more information about field-replaceable components.
See page 234 for a discussion of critical and offline logical drives.

Alarm Settings

Enable – Sounds for all conditons listed above.

Disable – Does not sound for any condition.

Silence – Stops the alarm from sounding for the current event. If another
event happens, the alarm will sound again.

To change Audible alarm settings:
1.

From the CLU Main menu, press 9.
The buzzer options appear.

----------------------------------------------------
Buzzer
1. Silence Buzzer
2. Disable Buzzer
R. Return to Previous Menu

Please enter your menu choice>

2.

Do one of the following:

To silence the buzzer (for the current event only), press 1 and Enter.

To disable the buzzer (off until enabled again), press 2 and Enter.
Silence/Disable/Enable buzzer(y/n)?>

3.

Press Y and Enter to confirm your choice.

If you disabled the buzzer, repeat the same procedure enable it again.