Promise Technology VTrak 15110 User Manual

Page 88

Advertising
background image

VTrak 15110 User Manual

80

Illegal Secondary Identify A target received a second Identify message with a

different LUN.

Message Parity Error

Detected possible parity error in message between
initiator and target.

Bus Reboot

The VTrak system has rebooted.

Connection Event
Notification

All events related to the Host PC-to-UltraTrak
connection.

UltraTrak Connection
Connected

Connection between Host PC and UltraTrak was
successful

UltraTrak Connection Lost Connection between Host PC and UltraTrak has

failed

Disk Event Notification

All events related to the disk drives.

Disk Down*

A disk drive has been set down due to some kind of
error.

Disk Plugged In

A disk drive has been plugged into the logical drive.

Disk Access Retry

The Controller repeats an attempt to access a disk
drive.

Disk CRC Error

A CRC error has occurred on a disk drive.

Disk SMART Failed*

A SMART error has been reported on a disk drive.

Disk ECC Error

A ECC error has occurred on a disk drive.

Disk Bad Sector*

A bad sector has been identified on a disk drive.

Disk Reserve Sector Error A error has occurred on the reserve sector of a disk

drive.

Disk Time Out

A disk drive has timed out.

Logical Drive Event
Notification

All events related to logical drives.

Create Logical Drive

A logical drive has been created.

Delete Logical Drive

A logical drive has been deleted.

Logical Drive Critical*

Malfunctioning disk drive, fault tolerance lost.

Logical Drive Offline*

Two malfunctioning disk drives, data access lost.

Logical Drive Migration
Started

A logical drive began expansion and/or change of
RAID level.

Item

Meaning

Advertising