Synchronize logical drive, Redundancy check – Promise Technology VTrak 15110 User Manual

Page 194

Advertising
background image

VTrak 15110 User Manual

186

**************PDM for Disk Array**************
Id

Disk Array Name

Mode

Size

---------------------------------------------------------------
1

Daniels

RAID5

237 GB

PDM for Logical Drive started
Press Enter key to return

6.

Press Enter to return to the Maintenance menu.
If the Maintenance Activity Monitor is enabled, you can watch the PDM
progress on your monitor.

Synchronize Logical Drive

Use this function to verify the integrity of your data across the physical drives that
make up your logical drive.

1.

Press 5 and Enter to access Synchronization.

Enter the Logical Drive ID>1
Start SYNC for LD 1(y/n)?>y

2.

Type the ID number for the logical drive you want to synchronize and press
Enter.

Logical Drive SYNC Started
Press Enter key to return

3.

Press Enter to return to the Maintenance menu.
If the logical drive was Functional when Synchronization began, you can
pause and resume the Synchronization process with this same function.

If the Maintenance Activity Monitor is enabled, you can watch
Synchronization progress on your monitor.

Redundancy Check

Use this function to verify the integrity of your data across the physical drives that
make up your logical drive.

1.

Press 6 and Enter to access Redundancy Check.

Enter the Logical Drive ID>1
Start RC for LD 1(y/n)?>y

2.

Type the ID number for the logical drive on which you want to run a
Redundancy Check and press Enter.

Logical Drive RC Started
Press Enter key to return

3.

Press Enter to return to the Maintenance menu.

Advertising