Chapter 8: Troubleshooting

233

Logical Drive Quick
Initialization Stopped

User aborted Quick Initialization. Normal.

Logical Drive Percent
Completed

Progress in percent of synchronizing or rebuilding a
logical drive. Normal

Enclosure Notification
Enclosure Power Down

Power switched OFF. Turn power ON.

Enclosure Power Up

Power is ON. Normal.

Enclosure Unknown Error Unspecified problem with the Controller. If this

message appears frequently, note any malfunctions
and contact Technical Support.

Enclosure Over
Temperature

Click on Enclosure1 in WebPAM to identify location of
overheat condition. Verify that there is ample space
around the enclosure. Check that all fans are running
and airflow is not obstructed. Correct any problems.

Enclosure Fan Stop

Click on Enclosure1 in WebPAM to identify failed fan.
Replace as needed.

Enclosure 3.3 Volt Range Go to Controller management > Enclosure

management > Voltage in CLU.
Or click on Enclosure1 in WebPAM to check power
supply status. Replace as needed.

Enclosure 5 Volt Range
Enclosure 12 Volt Range

Battery Temperature Rise Click on Enclosure1 in WebPAM to check for

overheat condition. Correct any problems.

Battery Temperature
Dropped

Normal.

Battery Capacity below
threshold

Replace Battery.

Battery Capacity Normal

Normal.

Battery Discharging

Could be a SEP problem. If this message appears
repeatedly, contact Technical Support.

Battery Maintenance
Mode

Normal.

Battery life ended

Replace Battery.

Event

Action