Access Data

EQN

20- 0- 3- 4-,

CLOSS

0,

BCHEQN

2.

BCEQN

SP and AU3 &C56 and C64 and PMD

CPDDN

8153337890 and 8153337890 - CMD and 8153337890 - PMD,

CPVDN2

8153337890 and 8153337891 - VI,

COE

CLASS1,

LINKOPT

DYNNOPAL,

BAPROF

0,

Note:

The SPID number field should contain only numbers. Do not enter dashes or other characters.
An example of a correct SPID is 001332783401. If the telephone company gives you two
identical SPIDs, enter the SPID only once, in the first SPID Number field. Leave the second
field blank. Number Type and Number Plan should always be set to Not Used in the United
States.

European Line Information

You will need to provide the following ISDN BRI line information when you install the LiveGateway software.
If you don’t have this information, it can be obtained from your service provider:

Signaling protocol (switch type), which can be:

ITR6 (Germany)

NET3 (Italy)

NET3 (United Kingdom)

VN3 (France)

Number type and number plan. Refer to the following chart for the values to enter.