Appendix E Parameters and Screens

IPmux-1/1E Installation and Operation Manual

E-18

IPmux-1 E1/T1 Configuration

Table E-12. T1 Configuration Parameters

Parameter Possible

Values

Remarks

Channel Status

Enable
Disable

Detection of LOS alarm
No detection of LOS alarm
Default value: Enable

Transmit Clock Source

Adaptive
Loopback

Internal

Adaptive clock regeneration
T1 recovered receive clock is used as the transmit
clock.
Local clock source is used.

Default value: Adaptive

Loopback State

Internal



External




Disable

Data received from the IP network side will be looped
back to the network transmit line. An unframed all ‘1’
code (AIS) will be transmitted in the T1 Tx path toward
the PBX. Incoming data from the PBX will be ignored.

Data received from the PBX at the receive T1 line will
be looped back to the T1 Tx path (toward the same
PBX), and will continue its way to the IP network. Data
coming from the IP network will be ignored.
No loopback. Regular operation.
Default value: Disable

Line Type


T1-D4


T1-ESF


Unframed

Framing mode and operation mode for each
configuration:
Framer will be configured to T1-D4 mode. Operation
mode will be set by Signaling mode field #6 to either
Fractional or Fractional with CAS (see Chapter 1).
Framer will be configured to T1-ESF mode. Operation
mode will be set by signaling mode field #6 to either
Fractional or Fractional with CAS (see Chapter 1).
Framer will be configured to pass through mode and
the operation mode will be set to unframed (see
Chapter 1).
Default value: T1-ESF

Line Code

B7ZS, B8ZS, AMI

Default value: B8ZS

Line Mode

DSU, CSU

Default value: DSU

Line Length / Tx Gain

DSU: 0-133, 134-266,

267-399, 400-533,
534-655

CSU: 0 dB, –7.5 dB,

–15 dB, –22.5 dB

Default value: 0-133 ft




Default value: 0 dB