IPmux-1/1E Installation and Operation Manual

Chapter 1 Introduction

Functional Description

1-11

Front Panel

The control interface and indicator LEDs are located on the front panel of
IPmux-1/1E. For further details see Chapter 2.

Rear Panel

User and network ports and power supply are located on the rear panel of

IPmux-1/1E. For further details see Chapter 2.

1.3 Functional Description

IPmux-1 supports a single E1 or T1 TDM interface; it provides TDM connectivity

across the IP network. A single bundle (group of timeslots) can be transmitted to a
predefined far-end bundle. IPmux-1 supports ICMP (ping), and generates ARP in

case of unknown next hop MAC addresses, answers ARP requests, and supports
802.3 Ethernet format.
IPmux-1E supports 4 BRI or 4 FXS ports for transparent connectivity over the IP

network.
Both IPmux-1 and IPmux-1E support Ethernet user port for user LAN connectivity.
Configuration and management are provided via the IPmux-1/1E local terminal,
Telnet or RADview management tool (SNMP).
Figure 1-9 shows a typical application for IPmux-1.

IP

IPmux-1

E1/T1 Port

IPmux-1

E1/T1 Port

10/100BaseT

100BaseF

100BaseF

10/100BaseT

Figure 1-9. IPmux-1 Functional Diagram

IPmux-1/1E works in conjunction with the rest of the IPmux product line (see

Figure 1-10). The combination of IPmux products provides up to 31 per E1 or
24 per T1 remote bundles, attached to one central IPmux-4/16 (see Figure 1-10).