Chapter 2 Installation

IPmux-1/1E Installation and Operation Manual

2-6 Installation and Setup

100-240

V

A

C

1A

T

250V

POW ER

I/O

3

:

CAUTION

IIS D N

S

1

2

3

4

Figure 2-9. IPmux-1E Rear Panel (BRI Option) for Two Ethernet Ports

Grounding

Interrupting the protective grounding conductor (inside or outside the instrument)

or disconnecting the protective earth terminal can make this instrument
dangerous. Intentional interruption is prohibited.

Before switching ON this instrument and before connecting any other cable,

the protective earth terminals of this instrument must be connected to the

protective ground conductor of the power cord.

Fuses

Make sure that only fuses with the required rated current and specified type, as
marked on the IPmux-1/1E rear panel, are used for replacement: 1.6A T 250V.
Whenever it is likely that the protection offered by fuses has been impaired, the
instrument must be made inoperative and secured to prevent any operation.

Location of Connectors

Interface connections are made from the IPmux-1/1E back panel, as shown in

Figure 2-2.
Table 2-1 lists the E1/T1 port pinout.
Table 2-2 lists the Ethernet port pinout.
Table 2-3 lists the Control port pinout.
Table 2-4 lists the ISDN-S connector pinout.
Table 2-5 lists the FXS connector pinout for RJ-11.

Warning