Chapter 2 Installation

IPmux-1/1E Installation and Operation Manual

2-2 Installation and Setup

The DC power source must be isolated from the mains supply by double or

reinforced insulation. A suitable fuse or a circuit breaker should be integrated in
the negative power-supply line.


Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at

least 10 cm (4 inches) clearance at the rear of the unit for cable connections. Make
sure that the ventilation holes are not blocked.
The ambient operating temperature of IPmux-1/1E is 0

o

to 50

o

C (32

o

F to 122

o

F),

at a relative humidity of up to 90%, non-condensing.

2.3 Package Contents

The IPmux-1/1E package contains the following items:
• IPmux-1/1E unit
• Power cord
• Kit containing hardware for mounting the unit in a 19-in rack (optionally

supplied)
− RM-25 for IPmux-1
− RM-27 for IPmux-1E.

Power Cable

IPmux-1/1E comes equipped with the power cord connected to the AC/DC
interface on the rear panel.

2.4 Equipment Needed

IPmux-1/1E needs no special tools for installation. A screwdriver is necessary when
mounting IPmux-1/1E in a 19-in rack.

2.5 Installation and Setup

Setting Jumpers

IPmux-1

In general, IPmux-1 internal jumpers and switches do not need to be configured
by the user. Therefore, removing the product cover is not required.