RAD Data comm IPmux-1 User Manual

Page 138

Advertising
background image

Appendix E Parameters and Screens

IPmux-1/1E Installation and Operation Manual

E-40

Ethernet Configuration/Statistics Menus

Table E-26. LAN Statistics – Two Ethernet Ports

Statistics Values

Description

MAC Address

Hard Coded

Port local MAC address

Mode

Half duplex, Full duplex

Port mode is set by either the default mode or via auto
negotiation results

Rate

10Mbps, 100Mbps

Port rate is set by either the default mode or via auto
negotiation results

Status

Not connected, Connected

Not connected: Link loss
Connected: Normal operation

Frames received

Total Frames

Total number of correct frames received

Total Octets

Total number of correct octets received

Oversize Frames

Number of frames that are too long, and CRC is valid

Fragments

Number of frames that are shorter than 64 bytes and
have an invalid CRC

Jabber

Number of frames that are too long and have an
invalid CRC

Dropped Frames

Number of dropped frames due to delivery problems

CRC Errors

The number of good frames with invalid CRC

Frames transmitted

Correct Frames

Total number of frames successfully transmitted

Correct Octets

Total number of octets successfully transmitted

Collision

A counter of successfully transmitted frames for which
transmission is inhibited by collision event, valid only
in half duplex mode.