IPmux-1/1E Installation and Operation Manual

Chapter 1 Introduction

Functional Description

1-23

Ethernet User Port

The Ethernet user port allows a user to aggregate both TDMoIP traffic and his
private network LAN traffic to a single Ethernet network connection without

requiring an access switch. This is a cost effective solution for MTU or small office
applications. A rate limiter to restrict user port traffic is supported.
IPmux-1/1E contains an internal switch where one of its ports is connected to a
TDMoIP interworking function, another internal switch port is used as the user

port, and the third is used as an Ethernet network port.

Internal

Switch

TDMoIP

E1 Port

Ethernet

Network Port

Ethernet
User Port

Figure 1-19. IPmux-1/1E with Ethernet User Port

Priority is always given to TDMoIP packets inside the internal switch.

Internal Switch Operation Modes

Bridge Mode (no user rate limiter)

In this mode the internal switch performs transparent bridging, ALL internal ports
learn, update the internal tables, and make forwarding decisions according to the

source MAC only (not MAC + VLAN ID).
VLAN tagged frames are supported, however forwarding decisions are based on

MAC only.

Rate Limiter Mode

In this mode a rate limiter is available to limit user port traffic. This feature is

valuable when a limited bandwidth DSL modem, for example, is used to extend
the Ethernet link (generally when the Ethernet link rate is limited/shaped to a lower

rate after IPmux). In this case TDMoIP packets will be dropped in the modem
even if it was prioritized at the IPmux internal switch. This is prevented by limiting

the user port to actual link rate minus TDMoIP bandwidth. The rate limiter can

limit user traffic at 50 kbps steps up to 5M and in 1 Mbps steps from 5M to 100M.
The internal switch (in the rate limiter mode) operates in the following way:
• The network port is in lock mode (no learning takes place). If this port must be

connected to a switch (not a hub), this is not a limitation, since all applications

involve connection to a backbone on an access switch.

• VLAN tagged frames are not supported (will be dropped)
• Access to the IPmux host for management is possible only from the network

port.