IPmux-1/1E Installation and Operation Manual

Chapter 4 Troubleshooting and Diagnostics

Diagnostic Tests

4-5

IPmux-1

ISDN S

Figure 4-4. IPmux-1E/BRI Internal Loop

To run a loopback test:

• Press the <Spacebar> on your keyboard to toggle between the values:

Internal/External /Disable

.

− Internal: Data received from the IP network side is looped back to the

network transmit line.

− External: Data received from the PBX at the receive ISDN S line is looped

back to the ISDN S Tx path (toward the same PBX). Data coming from the
IP network is ignored.

− Disable: No loopback. Regular operation.

Default value: Disable

FXS

Remote Loopback

You can set a remote loopback analog signal, per port, in IPmux-1E with FXS

interface. The analog signal is looped back towards the IP network.

Tone Injection

A 1 kHz tone, per port, is injected towards the local telephone set.

To run a test:

• Press the <Spacebar> on your keyboard to toggle between the values:

Remote Loopback/Tone Injection/Disable

.

Default value: Disable

Main Menu

2. Configuration

2. ISDN
Configuration

3. Channel

Configuration

1. Choose
Channel

3. Loopback

State

Main Menu

2. Configuration

2. ISDN
Configuration

3. Channel

Configuration

1. Choose
Channel

5. Testing