IPmux-1/1E Installation and Operation Manual

Chapter 2 Installation

Installation and Setup

2-3

IPmux-1E

The IPmux-1E FXS version needs NO user internal jumper configuration.
The IPmux-1E ISDN version contains jumpers for phantom feed (see Figure 2-1).

Open the case and check the positions of internal jumpers before the IPmux-1E

installation.

To open the IPmux-1E case:
1. Disconnect all the cables connected to the IPmux-1E.
2. Release the cover screws at the rear panel (one is near the POWER connector).
3. Slide the IPmux-1E top cover by pulling it straight out.

To set the IPmux-1E ISDN-S module jumpers:
If necessary, change the settings in accordance with the specific requirements of

your application:
• ENA – enable phantom feed
• DIS – disable phantom feed

The phantom feed ENA/DIS setting influences the IPmux-1E BRI operation mode.
When phantom feed is disabled, the S interface can be configured (through

software) to the TE or NT mode. When phantom feed is enabled, only the NT
mode is possible.

Only qualified and authorized service personnel should have access to the

inside of the unit.
Disconnect the unit from the power line and from all the cables before

removing the cover.
Line voltages are present inside IPmux-1E when it is connected to power.
Moreover, under certain external fault conditions, dangerous voltages may

appear on the lines connected to IPmux-1E.
Any adjustment, maintenance, and repair of the opened device under voltage

should be avoided as much as possible and, when inevitable, should be

carried out only by a skilled technician who is aware of the hazards involved.
Capacitors inside the device may still be charged even after it has been

disconnected from its source of power.

The IPmux-1E contains components sensitive to electrostatic discharge (ESD). To
prevent ESD damage, avoid touching the internal components, and before moving

jumpers, touch the IPmux-1E rear panel.

Caution

Warning

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Advertising