Chapter 5 Application Configuration Procedures

IPmux-1 5-9

Remember to press <Enter> after modifying each parameter. Press <S> to save

all changes on the menu.

E1/T1 Configuration

To configure E1/T1:
1. From the Main menu, select 2 Configuration.
2. From the Configuration menu select 2 E1/T1 Configuration (refer to

Figure 5-3).

3. Select Transmit Clock and choose Adaptive.
4. Select Line Type and choose CRC4 Disable.
5. Select Signaling Mode and choose CAS Disable.
6. Press <S> to save the configuration.
7. Press <Esc> a number of times to return to the Configuration screen.

Remember to press <Enter> after modifying each parameter. Press <S> to save

all changes on the menu.

DS0 Bundle Configuration

To create the bundles:
1. From the Configuration menu select 5 DS0 Bundle Configuration (refer to

Figure 5-4).

2. Select Time slot number and enter 1 – 10.
3. Select Time slot Current Status and choose Set.
4. Press <S> to Save.
5. Press <Esc> to return to the Configuration screen.

Remember to press <Enter> after modifying each parameter. Press <S> to save

all changes on the menu.

Bundle Connection Configuration

To link the bundles to IPmux-4:
1. From the Configuration menu select 3 Bundle Connection Configuration

(refer to Figure 5-5).

2. Select Connection Status and choose Enable.
3. Select Destination IP Address and enter the IP Address of IPmux-4.

Note

Main Menu

2. Configuration

↓↓↓↓

2. E1/T1

Configuration

Note

Main Menu

2. Configuration

↓↓↓↓

5. DS0 Bundle
Configuration

Note

Main Menu

2. Configuration

↓↓↓↓

3. Bundle
Connection

Configuration