Connecting the power, Gnd +24 v – Zebra Technologies TTP 7030 User Manual

Page 18

Advertising
background image

Installation
Connecting the Power

18

P1003636-002

TTP 7030™ Technical Manual

10/05/2009

Connecting the Power

Using the Zebra power supply (see Ordering Numbers

on page 127

for ordering number):

1.

Make sure the line voltage selector on the power supply is set to your local line voltage
(only PSU 01035-014).

2.

Connect the cable from the power supply to J8.

3.

Connect the power cable to the line outlet.

4.

Apply power to the printer.

If you use another type of power supply unit, connect the voltages as shown in

Figure 6

.

At the printer end of the cable, use an Tyco Mate-N-Lok connector housing and two contact-
sockets:

Figure 6 • Power Connection

Table 1 • Current Consumption

Important •

The protective ground and the 24V ground must be separated in the power

supply to avoid ground loops!

Tyco No. 350777-1

Tyco No. 350689-1

Idle

150 mA

150 mA

Standard text printing

2.5 A average

3.5 A average

All black printing

8.5 A

11 A

GND

+24 V

Advertising