Ee parameter, 15 to 30 – Zebra Technologies TTP 7030 User Manual

Page 77

Advertising
background image

77

Default Parameter Settings

Print Setup

10/05/2009

TTP 7030™ Technical Manual

P1003636-002

Controls what the printer does with buffered data:

Adding history pulse enhances print quality. Dividing burning into two burn pulses reduces the
peak current consumption.

The line spacing is normally set by the font height. With this parameter you can set a line
spacing that is higher that the font height. Line spacing settings lower than the font height will
be ignored.

Store which font number is used if no font is specified. Font is selected using

Font Selection

on page 77

. Selecting an invalid font gives a software error status message (invalid index).

Stores 16 different TAB stop positions. The position is set in increments of 2.5-mm.

Tab position 255 sets a tab stop on the last position of the line. Use this if you want underline
or reversed text to extend across the full paper width.

To set all tab stops at once, follow the procedure

Set several parameters at once on page 55

.

To move a single tab stop, use the set parameter command <ESC>&P.

Default positions are one TAB on each cm; that is parameter values 4, 8, 12 etc.

10

1 Default

Print Head Pulse Control

0 Min
3 Max

<ESC>&P<10><0>

1 burn pulse + history

<ESC>&P<10><1>

1 burn pulse

<ESC>&P<10><2>

2 burn pulses + history

<ESC>&P<10><3>

2 burn pulses

13

0 Default

Line Spacing

0 Min

30 Max

<ESC>&P<13><30>

30 pixels or font height, whichever is the largest

14

0 Default

Font Selection

0 Min
7 Max

15 to 30

- Default

Tab Stop

1 Min

255 Max

Example •

This example sets the first tab stop 25 mm from the left margin.

<ESC>&P<15><10>