73

Default Parameter Settings

Serial Interface Set-Up

10/05/2009

TTP 7030™ Technical Manual

P1003636-002

Serial Interface Set-Up

Sets the communication speed on the serial interface.

Selects if 7-bit ASCII, or 8-bit, is used on the serial interface.

Select what parity to use on the serial interface.

1

96

Default

Baud Rate

24

Min

11

Max

Note •

The new value is not valid until the parameters are stored and the printer restarted.

<ESC>&P<1><24>

2400 bps

<ESC>&P<1><48>

4800 bps

<ESC>&P<1><96>

9600 bps

<ESC>&P<1><19>

19200 bps

<ESC>&P<1><38>

38400 bps

<ESC>&P<1><57>

57600 bps

<ESC>&P<1><11>

115200 bps

Note •

If you set an invalid value, the baud rate will return to the previous value.

2

8

Default

Data Bits

1

7

Min

8

Max

<ESC>&P<2><7>

7-bits (characters 0-127)

<ESC>&P<2><8>

8-bits (characters 0-255)

3

0 Default

Parity

1

0 Min
2 Max

<ESC>&P<3><0>

No parity

<ESC>&P<3><1>

Odd parity

<ESC>&P<3><2>

Even parity

Advertising