Parameters used – Zebra Technologies TTP 7030 User Manual

Page 89

Advertising
background image

89

Page Setup

Parameters Used

10/05/2009

TTP 7030™ Technical Manual

P1003636-002

Parameters Used

Parameter n35 Black Mark

Enables/disables black mark check.

Parameters n37 and n38 - Page Length Minimum

Measure the distance from the trailing edge of one black mark to the trailing edge of the next.
The resolution is 0.125 mm so multiply the distance by 8, then calculate the value to enter as
n37 and n38.

Parameter n39 – Max Black Mark Length

Measure the height of the black mark. The resolution is 0.125 mm so multiply the black mark
length (in millimeters) by 8 and enter the value as n39.

Parameter n40 – Min Black Mark Length (Garbage Filter)

This parameter is actually a filter to filter-out garbage on the paper. If a spot is smaller than this
value, it will not be regarded as a black mark. 1. About ⅓ of the black mark length is usually a
suitable setting.

Example •

If the page length is 100mm, (100 x 8) / 256 = 3.125.

n37 is the integer value, that is 3, while

n38 is the fraction, 0.125 x 256 = 32

Advertising