Programming
Status Reporting Commands

60

P1003636-002

TTP 7030™ Technical Manual

10/05/2009

Results in a 2-byte response representing the version of the installed firmware.

The first byte represents major versions, and the second byte minor versions.

If no firmware is loaded, the printer will answer with 00h.

Results in an 6-byte response representing the serial number of the printer’s control board.

Results in a 1-byte response representing the control board revision. A minus sign indicates
that no revision has been made, while A indicates the first revision, and so on.

ESC ENQ 7

Firmware-version Enquiry

1B 05 07

Hex

27 5 7

decimal

Example •

Send

<ESC><ENQ><7>

Read

 <2><29>

That is, a response with the value <1><29> indicates version 2.41.

ESC ENQ 9

Control Board Serial-number Enquiry

1B 05 09

hex

27 5 9

decimal

Example •

Send

<ESC><ENQ><9>

Read

00 00 02 02B 0C6 028 (hex), or 0 0 2 43 198 40 (dec)

ESC ENQ 10

Control Board Revision Enquiry

1B 05 0A

hex

27 5 10

decimal

Example •

Send

<ESC><ENQ><10>

Read

n

Where n can be ‘A’ (ASCII) or 41 (hex) or 65 (dec)