Digital Mixers With a [REMOTE] Connector

Connect the mixer’s [REMOTE] connector to the MY16-ES64 or similar EtherSound interface card via a
9-pin D-sub cross cable, and make the appropriate EtherSound connections between the interface
card and DME units. Use an Ethernet cable connected to the [NETWORK] connectors to make
connections between DME series units.
The port to be used for head amp control via direct serial communication with a DME unit is specified
by the [Internal HA Control] parameter in the “Misc” tab in the “Utility” dialog box (

page 165

). Select

“Slot 1” when the DME unit to be used for serial communication is a DME24N, or “EtherSound” if it is a
DME Satellite unit. The settings for all other DME units should be “OFF”.

Use the AVS-ESMonitor software from AuviTran to specify the EtherSound serial communication
settings for both the digital mixer’s interface card and the interface card installed in the serially
connected DME unit.

• Serial Communication mode: Unicast for bidirectional operation.
• Set the digital mixer’s interface card to “Mode 3,” and the DME unit to be used for serial

communication to “Mode 2.”

• Baud Rate: 38400

In order to turn serial communication off for the interface cards installed in all other DME units, set the
Serial Communication mode to “Slave”.

NOTE

• DME24N units with firmware version V3.04 or later are compatible.

• You can download the AVS-ESMonitor software from the AuviTran website.

http://www.auvitran.com/view.php?products_AVS-ESMonitor.php

DME8i-ES

DME4io-ES

DME24N

Ethernet

EtherSound

MY16-ES64

MY16-EX64

MY16-ES64

Network

Switch

(mode 3)

(mode 2)

Digital Mixer

D-Sub 9-pin