Chapter 3 Main Panel Window

DME Designer Owner’s Manual

155

5 Operation Security

Sets the functions that can be used by the user selected on the [User List] to the left. Selecting
a checkbox enables use of the corresponding function.

• [Edit]

You can change the following settings: editing in the Designer window, user control edit, user
defined parameter edit, word clock, scene edit, GPI and MIDI.

• [View DME Design Window]

Allows display of the Designer window.

• [Control Component Editor]

Allows parameter editing in the component editor.

• [View Component Editor]

Allows display of the component editor.

• [Change Configuration]

Allows switching between configurations.

• [Synchronization]

Allows synchronizing with the DME or SP2060 unit.

• [View Log Window]

Displays the “Event Logger” window.

• [Scene Store/Recall Level]

Sets the level at which scenes can be stored and recalled. Click the [

▲] and [▼] buttons or

enter a number into the box to set the level. While levels 1 through 10 are available, the range
of levels that can be actually set varies according to the level of the user doing the setting.
When a user is created, automatically this is set to “One level lower than the user above.” The
initially set level is the highest level that can be set for that user.

• [User Control Level]

Sets the user control level. Click the [

▲] and [▼] buttons or enter a number into the box to set

a level from 1 through 10. While levels 1 through 10 are available, the range of levels that can
be actually set varies according to the level of the user doing the setting.
When a user is created, automatically this is set to “One level lower than the user above.” The
initially set level is the highest level that can be set for that user.

[OK] Button

Applies any setting changes and closes the window.

[Cancel] Button

Closes the window without changing any settings.