DME Firmware Update

You can update the DME or SP2060 unit, ICP1 firmware using the [Firmware Update] command on the
[Hardware] menu. When you move the mouse cursor over the [Firmware Update] command on the
[Hardware] menu, a submenu is displayed.

When you select [Program+Component] or [Recovery Update] on the submenu, the folder select
dialog box will be displayed.

When performing a firmware update, connect the DME or SP2060 unit, ICP1 and the computer.

When the DME or SP2060 unit, ICP1 update is finished, the DME or SP2060 unit, ICP1 will be
automatically restarted. You also need to restart DME Designer.

NOTE

When performing the DME or SP2060 unit firmware update, connect the DME or SP2060 unit and the computer by USB or
Ethernet. The USB-MIDI or DME-N Network Driver must be installed in the computer.

NOTE

To perform the ICP1 firmware update, the ICP1 and the device group master DME unit must be connected by Ethernet. In
addition, the device group master DME unit must be connected to the computer as described above.

NOTE

If the DME64N/24N has been updated from V1.07 or lower to V1.10 or upper, perform the update twice. Because the text
display data in the DME64N/24N unit is changed, text display for Japanese is not possible with one update only.

NOTE

Firmware Update may become impossible if the [Remaining Memory] value (the amount of remaining DME memory)
becomes too small. If this occurs, delete unwanted data such as DME File Storage files, Library data, and scene data to
increase the amount of available memory.

NOTE

You can download the latest firmware from the following Yamaha Pro Audio website.