SENA LS110 User Manual

Page 32

Advertising
background image

32

-------------------------------------------------------------------------------

Serial port configuration

-------------------------------------------------------------------------------
1. Baud rate : 9600
2. Data bits : 8
3. Parity : None
4. Stop bit(s) : 1
5. Flow control : Hardware
6. Inter-character timeout : 0
7. Host mode : TCP Client
8. Destination IP : 0.0.0.0
9. Destination port : 7001
10. Inactivity timeout : 0
11. Cyclic connection : 0
12. DTR behavior : Always HIGH
13. DSR behavior : None
14. Allowed IP : 0.0.0.0
15. Allowed subnet : 0.0.0.0

<ESC> Back, <ENTER> Refresh

---> 8

Enter destination IP address
---> 192.168.23.30

-------------------------------------------------------------------------------

Serial port configuration

-------------------------------------------------------------------------------
1. Baud rate : 9600
2. Data bits : 8
3. Parity : None
4. Stop bit(s) : 1
5. Flow control : Hardware
6. Inter-character timeout : 0
7. Host mode : TCP Client
8. Destination IP : 192.168.23.30
9. Destination port : 7001
10. Inactivity timeout : 0
11. Cyclic connection : 0
12. DTR behavior : Always HIGH
13. DSR behavior : None
14. Allowed IP : 0.0.0.0
15. Allowed subnet : 0.0.0.0

<ESC> Back, <ENTER> Refresh

---> 9

Enter destination port number
---> 7004

Figure 4-4 Set up remote host information

Cyclic connection interval

The time interval at which the LS110 will try to connect to the remote host regardless of the

existence of incoming data from the serial port. If the interval is specified with a valid value other

than 0, the function is enabled. The time interval will be the specified value by the unit of second.