C.6 TCP Server Mode Operation Troubleshooting

Problem

Cause

Action

IP configuration of
remote host is invalid

Check if IP configuration of the remote host is valid

Host mode of the
LS110 serial port is not
TCP server

Change the host mode of the LS110 serial port to TCP server or
TCP server/client

IP address of the
LS110 or TCP port
number is wrong

Specify valid IP address and TCP port number of the LS110

DSR option is set but
DSR input is not high

Disable DSR option or make DSR input of the LS110 high

Cannot connect to the
LS110

TCP connection with
the other host is
established already

Close established TCP connection or connect later

C.7 Serial Communication Troubleshooting

Problem

Cause

Action

Serial data are not
transferred by
TCP/IP immediately

Too large inter-character
timeout

Set inter-character timeout with smaller value

Cannot
communicate with
the LS110

Invalid serial port
configuration

Check if serial port configuration of the LS110 are the same
with that of the serial device

Invalid data
transferred

Invalid serial port
configuration

Check if serial port configuration is correct.